The ZEMIC L6D Single-Point Load Cell is ideal for pricing scales, counting scales, bench scales, and other electrical weighing devices. This ZEMIC L6D load cell is colorless anodized and made of an aluminum alloy. Offering a wide range of capacities, this load cell also has a cable length of 10 ft. 

Interchangeable Products: Rice Lake RL1521A, Celtron LPS

NTEPLogo

Specifications

  • Max No. of Verification Intervals: 5000 Nmax
  • Min Load Cell Verification Intervals: Class III Vmin
  • Output Sensitivity: 2.0 ± 0.02 mV/V
  • Input Resistance: 406 ± 6 ohms
  • Output Resistance: 350 ± 3 ohms
  • Insulation Resistance: =5000 (50 VDC)
  • Temperature: Compensated 14° to 104° F / -10° to 40° C
  • Operating -31° to 149° F / -35° to 65° C
  • Excitation, Recommended: 5~12 V (DC) Excitation, Max: 18 V (DC)
  • Safe Overload: 120% Full scale
  • Ultimate Overload: 300% Full scale
  • Seal Type: Environmentally sealed - IP65
  • Cable Length: 10 ft

Max Cell Capacity

  • 35 kg
  • 40 kg
  • 50 kg
  • 3 kg
  • 5 kg
  • 6 kg
  • 8 kg
  • 10 kg
  • 15 kg
  • 20 kg
  • 30 kg
Loading...