DD700/DD1010/DD1050/DD2050 Gateway Profinet Io (External)
Details
Functions
Serial communicator/gateway
Serial RS232/485 port
Baud rate -- 1200bps to 128kbps
Max stations -- 31
Isolation -- Galvanic isolation
Max nodes -- 31
Modbus RTU
Modes -- Master
Functions supported -- 1 / 2 / 3 / 4 / 5 / 6 / 15 / 16 / 22 / 23
Max number of commands -- 150
Input data size -- 1500bytes
Output data size -- 1500bytes
Environment
- Installation altitude -- up to 2000m
PROFINET
Mode -- PROFINET IO-Device (slave)
Class -- A / B
Communication channels -- Real Time Channel (RT)
Input data size -- 1024bytes
Output data size -- 1024bytes
Minimum cycle time -- 1ms
Max number of connections -- 1 IO Controller Application Relationship + 2 Device Access Application Relationships
Netload class -- Class III
I&M records -- Manufacturer data (I&M0) / Tag information (I&M1) / Date/Time (I&M2) / Description (I&M3)
SNMP -- Available
GSDML File -- Available
Certification -- Approved
Configuration software -- Web based configuration
Configuration ports -- Dedicated 10/100Mbit RJ45 Ethernet configuration port and Ethernet ports
- Security
Secure boot -- Ensures software authenticity
- Security switch -- Physical switch that enable/disable access to the web based configuration interface
Mean time between failure (MTBF) -- >1500000hr; Telcordia Method I Case 3 at 30°C
Design
Serial + PROFINET
Ethernet dual-port cut-through sw.
4 x LED indicators (gateway status / network/serial status)
2 x push-buttons (reset / security sw.)
Supply voltage (DC)
12Vdc-30Vdc (24Vdc nom.)
Connection type
2 x RJ45 connectors (10/100Mbit/s Ethernet; full duplex; galvanic isolation)
1 x 7-pole plug-in connector (serial RS-232/RS-485)
1 x 3-poles plug-in screw connector (power)
Protection functions
reverse voltage protection
short-circuit protection
Communication protocol
PROFINET
RS-232
RS-485
Mounting mode
DIN rail (35/7.5 or 35/15) mounting
Speed
100Mbit/s (PROFINET)
Degree of protection
IP20
Dimensions
H144mm x W27mm x D98mm
Material
Plastic housing (ABS / PC)
Ambient air temperature for operation
-25...+70 °C
Ambient air temperature for storage
-40...+85 °C
Current consumption
400mA (12Vdc; max.)
160mA (24Vdc; typical)
Contents
power connector
start-up guide
compliance information sheet
Compliant with standard(s)
CE 2014/30/EU
UL
UL94 V-0
KC
WEE
cULus file E214107
EMC
- EN 61000-6-2
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6
- EN 61000-6-4
- EN 55032
Environment
- IEC 60068-2-1 Ab
- IEC 60068-2-2 Bb
- IEC 60068-2-1 Ab
- IEC 60068-2-2 Bb
- IEC 60068-2-14 Nb
- IEC 60068-2-30 Db
- IEC 60068-2-78 Cab
- IEC 60068-2-78 Cab
Vibration and shock
- IEC 60068-2-27
- IEC 60068-2-6
EU - Declaration of Conformity
- EN 61000-6-4(2019) Emission standard for industrial environment
- EN 55016-2-3(2017) (Class A)
- EN 55032(2015) (Class A)
- EN 61000-6-2(2019) Immunity for industrial environment
- EN 61000-4-2(2009)
- EN 61000-4-3(2020)
- EN 61000-4-4(2012)
- EN 61000-4-5(2014) + A1(2018)
- EN 61000-4-6(2014)
UK - Declaration of Conformity
- EN 61000-6-4(2019) Emission standard for industrial environment
- EN 55016-2-3(2017) (Class A)
- EN 55032(2015) (Class A)
- EN 61000-6-2(2019) Immunity for industrial environment
- EN 61000-4-2(2009)
- EN 61000-4-3(2006) + A1(2008) + A2(2010)
- EN 61000-4-4(2012)
- EN 61000-4-5(2014) + A1(2018)
- EN 61000-4-6(2014)
Benefits
Modbus RTU Master - Industrial Ethernet
- Integrate your serial RS-232/485 based industrial devices and equipment to EtherCAT / Ethernet/IP / Modbus TCP or PROFINET control systems without any changes to the device -- Just connect & configure and you're done.
- The communicator can transfer large amounts of data is fast to configure thanks to its' drag and drop web interface and is built on trusted Anybus technology.
- Selectable industrial Ethernet network (Ethernet/IP / Modbus TCP / PROFINET or EtherCAT)
- Web-based drag and drop configuration interface
- -25...+70°C industrial temperature range
- Powered by award winning NP40 network processor
Convert almost any type of serial protocol
- The Communicator can convert both standard serial protocols such as Modbus RTU and proprietary serial request/response or produce/consume based protocols.
Transfer up to 1500bytes of data in both directions
- Demand for more data is constantly growing and the Communicator has been equipped to handle the challenge.
- It can transfer up to 1500bytes from the PLC to the Gateway and 1500bytes from the gateway to the PLC / 3000bytes in total (network dependent).
- Support for up to 150 Modbus commands means even complex configurations with multiple nodes can be handled with ease.
Drag and drop web interface
- To make sure you spend as little time as possible configuring the Communicator -- we have built a graphical and responsive web-based user interface.
- No software needed to be installed -- just open your favorite web browser and get started.
Industrial temperature range
- An industrial operating temperature range of -25...+70°C ensures the Communicator can excel under harsh conditions.
Powered by proven NP40 technology
- The Communicator is built on the award-winning and proven Anybus NP40 network processor.
- With hundreds of thousands NP40s used in Embedded applications across the world -- it is the industry benchmark for reliable industrial communication.
Security switch
- Even with sophisticated security measures human error is still the main cause of security breaches.
- To simplify security -- we added a physical security switch on the Communicator.
- It locks your configuration and prevents any access to the web-based configuration interface.
- Just flip it when your configuration is done and watch the padlock LED on the product light up.
Ethernet configuration port
- With a dedicated Ethernet configuration port you don't need any special configuration cable. In addition it is easy to connect to the gateway to monitor network traffic.
Optimized for DIN-rail mounting
- The slim form factor / front facing network connectors / screw in serial cable connector and the neat cable tie ensure it is fast and simple to install and connect the Communicator.
Diagnostics
- When opening the Communicator web interface you immediately see the status of the PROFINET connection and serial connection.
- You can even see the status of individual serial nodes. It's also equipped with a serial log and an event log for further analysis.
Support
- Sometimes you run into a problem where you need help -- That's why we have included a support page in the user interface with contact information.
- There is even a button to generate a support package to simplify troubleshooting.
Serial features
- Selectable RS-232/485 interface
- 3ms serial update rate (selectable)
- Visual I/O data map to map serial data to industrial network
- Drag and drop frame builder for custom protocols with no programming required
- Trigger serial transactions from control system with triggers
- Transfer data between serial nodes with general data area
- Monitor and control serial nodes from control system with live list and data exchange control
- Ability to import Communicator Classic configuration file
Common Ethernet features
- Cover multiple protocols with a single gateway and reduce storage costs
- Supports Ethernet/IP adapter / EtherCAT slave / Modbus TCP server or PROFINET IO device (Modbus TCP server pre-loaded)
- Transfer 1448bytes with Ethernet/IP / 1486bytes with EtherCAT / 1500bytes with Modbus TCP and 1024bytes with PROFINET to and from the gateway
- Download your protocol firmware from the product support page (free)
- Load your protocol firmware via the gateway web-configuration interface
- Dual RJ-45 Ethernet ports with 10/100Mbit full duplex
- Daisy chaining with integrated switch
Application type
Typical serial applications include variable frequency drives / sensors / actuators / human machine interfaces / barcode readers / RFID readers and industrial scales among others.
Humidity
0-95% relative humidity (RH; non-condensing)